Type 1 1.1/1.1KV Individually Screened
Applications :
- These individually copper screened cables are used for wiring of machines, or between machines and equipment where PVC is suitable.
Standards :
Construction :
-
Conductors Stranded copper conductor. Insulation PVC. Individual Composite Screen (earth conductor) Tinned annealed copper braiding interwove with polyester yarn. Binding Polyester tape. Sheath PVC sheath.
Dimensions and Weight :
-
Number of
CoresNominal
Conductor
AreaStrand Size Insulation
ThicknessCore Screen Thickness
of SheathNominal
Overall
DiameterNominal
WeightStrand Size Area of
Screenmm² No/mm mm mm mm² mm mm kg/100m Type 1 - Individually Screened 3 1.5 30/0.25 0.8 0.20 3.5 0.8 10.1 16 4 1.5 30/0.25 0.8 0.20 4.6 0.8 11.1 21 3 10 77/0.40 1.0 0.20 6.8 1.0 18.6 59 4 10 77/0.40 1.0 0.20 9.0 1.0 20.5 75 3 16 126/0.40 1.0 0.20 7.9 1.3 21.6 84 4 16 126/0.40 1.0 0.20 10.6 1.3 23.7 110